back to product overview

Analytical sample gas lines with RSL fitting
H 300 series350 °C
Application potential: Maintaining the temperature of motor exhaust, CO2 measurements, industrial exhaust gasses, blast furnace exhaust gasses, air testing, environmental testing, etc.
This heated sample-extraction line prevents condensation from forming or a temperature drop below the dew point, thus no gas components are eliminated or lost.
Operating temperature | 100°C / 200°C / 250°C / 350°C |
Rated voltage | 230 V AC/DC (other voltages up to 500 V) |
Power rating | Watt/metre, see type codes |
Inner core DN 4 – 12 mm | up to 250°C PTFE or PFA above 250°C stainless steel see Inner cores analytics |
Connection fitting | RSL 1.4571 steel, for cutting ring screw, without transition, see table |
Heating | heating conductor, structure according to DIN, moisture-proof with PE conductor braiding; > 250°C not moisture-proof |
Thermal insulation | depending on the operating temperature heat stabilized, close-pore silicone foam or thermal fleece, elastomer foam |
Outer protective braiding | polyamide black, options - see Outer protection |
Hose end caps | PA hard cap or elastomer cap |
Temperature sensor | Fe-CuNi type J, NiCr-Ni type K, PT 100 and integral control system (HTI) possible |
Connection cable | 3 m |
Plug connection | according to specification |
Production lengths | up to 100 m |
Protection type | IP65 (EN 60529), protection class I |
Tolerance | ±10°C |