back to product overview
Controller / limiter combination
HT 41 / 42 series
As a result of their free configurability and compact design, the HT 41 / 42 self-programmable temperature controllers are universal controllers in machine, system and apparatus applications.
In the design of this device, particular attention was paid to the limiter function with a permanent shutdown for unattended operation according to DIN/VDE 0721 and to non-contact switching of 3680 Watt.
Voltage supply | 230 Volt AC / 60 Hz, option 115 Volt |
Switching power | 3680 Watt, 16 A |
Sensor types | Fe-CuNi (J), NiCr-Ni (K) with reference point compensation, sensor breakage protection and sensor polarity control, PT100 2-wire DIN/IEC |
Tolerance | 0.1% – 0.2% of full range |
Controller outputs | elect. switch (controller) (16 A), triac |
Alarm outputs | alarm output relay 6 A, limit comparator Y3, ±10 K from setpoint |
Controller response | P-PID |
Limiter function | Signal via 2nd PT100 |
Cutout temperature Limiter | 50°C – 500°C adjustable, actuates 16 A mechanical relay |
Display actual/target value | 4-digit LED display (13 mm) |
Measuring range | -199 to +999 digits |
Deviation display | 7 LED ±12°C flashes |
Operation | foil keypad 4 push buttons |
Housing material | Makrolon |
Housing dimensions | 160 x 80 x 56 mm (W x H x D) |
Mounting plate dimensions | 160 x 100 mm (H x W ), serves as a heat sink |
Fastening | 4 bores for M4 screws |
Protection type | IP65 (EN 60529), protection class I |
Type HT41 cable inputs/outputs | 8+PE-pin socket HANQ8 / load mains cable 1.2 m with German Schuko mains plug |
Type HT42 terminal connections | KV screw connectors without mains cable |
Option | external setpoint input |
Setting ex works Sensor type PT100 | |
Type | Control range |
HT 41 | 0 – 200°C |
HT 42 | 0 – 200°C |
These parameters can be reprogrammed by the customer, or we will supply the setting as required (additional charge).