Flexible heating jackets
HFM series600 °C
The flexible heating jackets are constructed from heating tape and insulation and are suitable as trace heaters for customer pipes, also pre-shaped pipes. Heating of bundles of pipes is also possible.
The HFM heating jackets are slid onto the pipes to be heated, so the customer has a heating system that is easy to install and can be replaced.
Operating temperature | from frost protection to 600°C |
Rated voltage | 230 V AC (other voltages uo to 500 V) |
Rated power | depending on configuration |
Heat insulation | up to 250°C silicone up to 450°C textile glass up to 600°C silicate fibre |
Heating jacket | lengths 0.3 m up to approx. 10 m; optionally can also be split into individual segments, so that greater lengths or complete installations can be incorporated in the system. |
Temperature sensor | Fe-CuNi type J, NiCr-Ni type K, PT100 and integral control system (HTI) possible |
Pipe diameter | from capillary to 50 mm outer diameter (larger diameters on request) |
Inner hose | flexible metal corrugated hose |
Bend radii | adaptable to the heating system |
Connecting cable | 1.5 m |
Plug connection | optional |
Temperature control from our controllers, see chapter Control technology.